0102
China EL Series BMC DMC Insulators for High-Voltage Safety - Reliable Supplier from a Leading Factory
EL Series Insulator
Insert conventional materials, such as copper and iron. Stainless steel and aluminum inserts can be customized;
Products in the attached table are conventional products, while the other height size can be customized ;
'BD' in the attached table means the product's bore depth; it can be customized for other bore depth requirements ;
'Tightening torque' in the attached table means the torque installation; it can be customized for a greater torque demand;
The nominal voltage in the attached table refers to the IEC: 60355 standard; it can be customized for higher voltage requirements;
Actual performance parameters, dimensional tolerances, and appearance colors subject to the specific drawings;
| Part No. | EL7060M12A | EL15065M10M12 | EL6060M12 | ||||||||
| END diameters(A/B) | mm | 60 | 65 | 60 | |||||||
| Height(H) | mm | 70 | 150 | 60 | |||||||
| Rated voltage (AC) | KV | 3 | 13.8 | 2 | |||||||
| Withstand voltage (AC) | KV | 20 | 50 | 13 | |||||||
| Inserts arrangement | Top | A1 | M12 | / | M12 | ||||||
| A2 | / | M10 | / | ||||||||
| A3 | / | / | / | ||||||||
| AX | / | 36 | / | ||||||||
| AY | / | / | / | ||||||||
| BOTTOM | B1 | M12 | M12 | M12 | |||||||
| B2 | / | / | / | ||||||||
| B3 | / | / | / | ||||||||
| BX | / | / | / | ||||||||
| BY | / | / | / | ||||||||
Other sizes can be inquired from customer service
Contact us
Frequently Asked Questions (FAQ)
What materials are available for the EL Series Insulator inserts?
Conventional insert materials include copper and iron. However, stainless steel and aluminum inserts can be customized according to your requirements.
Can the height and dimensions of the insulators be customized?
Yes, the sizes listed in the specifications table are conventional products. Other height dimensions and configurations can be customized based on your needs.
What does "BD" refer to in the technical table?
"BD" stands for the product's bore depth. Custom bore depths are available if the standard specifications do not meet your application requirements.
Is it possible to request a higher tightening torque configuration?
Yes, the tightening torque indicated in the table represents standard installation values. We can customize the insulators to support greater torque demands.
What standard is the nominal voltage rating based on?
The nominal voltage values in the table refer to the IEC: 60355 standard. Higher voltage configurations can also be customized upon request.
How do I verify the final performance parameters and dimensions?
Actual performance parameters, dimensional tolerances, and appearance colors are subject to the specific product drawings. Please contact our support team to get the detailed drawings.